• 리얼타임 릴레이 타이머 DC5V

리얼타임 릴레이 타이머 DC5V

12,000 13,000
원산지
중국
배송정보
3,000원 (조건부배송) 지역별 추가배송 주문시결제(선결제)
택배 / 화물배송 / 방문수령 / 퀵배송

 Specification

- 리얼타임 릴레이 타이머 제어 모듈
- input Voltage : 5 ~ 60V
- 5단계 제어 설정 가능
- 버저 내장으로 경보기능  

 

* 본 제품을 사용하시기 위해서는 제품에 대한 이해도가 필요햡니다.  

Mode introduction:
OPE: relay closing time point, CLE: relay off time point
Time period: PE-1 ~ PE-5 5 time periods (OPE to CLE is a time perio
d)

Product parameters:
P-1: The relay closes or outputs pulses every day to the OPE time point, and the relay turns off or outputs pulses to the CLE time point.
P-2: set the day, to the OPE time point when the relay closed or output pulse, to the CLE time point when the relay disconnect / or output pulse 
P-3: set the date of the month, to the OPE time point when the relay closed or output pulse, to the CLE time point when the relay is off or output pulse
 P-4: Set the date 1 to date 2, start every day at the OPE time point, end to the CLE time point, relay action or output pulse
 P-5: As with P-4, only the month can not be set
 First, how to set the time?  In the time to run the interface, press the DOWN button for a while: 
Step 1: Select the time period: PE-1 ~ PE-5 Press UP and DOWN to select; 
Step 2: Press the SET key to select the mode: P-1 ~ P-5 (Set this time period to the corresponding mode) by pressing the UP and DOWN keys. ("----" means to block this time period) 
Note: Each time period can be repeated from the "----", P-1 ~ P-5 one of the optional; For example,you can let five time periods at the same time work in the P-1 mode, or let Time period 1 work in P-1 mode, time period 2 work in P-2 mode and so on. 
Step 3: After the mode selection is finished, press the SET key to enter the time period setting interface, set the interface in the time period, press the SET key to switch the parameter, "OPE" start time point, "CLE" end point, "dAE" date information;
 Step 4: After setting the parameters to exit the settings, press the SET button for 2 seconds to release, automatically check whether the parameter settings are legal, legal to save the parameters, return to the time to run the interface; if the parameter is wrong, "ERR" reminder (for example, stop time or Date <= start time or date), return to the parameter setting interface;

Additional features: Each "time period" can be set individually
 In the specific parameter setting interface (after the second step), press the STOP button to switch the output mode: 
OUT1: Start time point turns on the relay, the end time is off the relay 
OUT2: Outputs 1S pulse to start or end time
 
In the specific parameter setting interface (after the second step), press the STOP button for a while to switch the ringing mode: 
BLL0: Ring disable
 BLL1: Ring enable 
Note: When the bell rings, press any button to stop the ring 
STOP key function expansion:
Relay enable mode:
 
1. ON: enable relay on; 
2. OFF: Do not turn on the relay, it is always off;
Press the STOP button on the time display interface to switch between ON and OFF, the current status will flash, and then return to the main interface. (This function is the emergency stop function, press once to close the closed relay)
 
After the relay is disabled, the product can be used as an alarm clock.
 
Sleep mode:
1. C-P sleep mode: within five minutes, without any operation, the digital tube automatically shut down the display, the program normal operation; 
2. O-d normal mode: digital tube is always open display;
Press the STOP button for a while after 2 seconds to release, to achieve C-P and O-d state of the switch, the current state will flash, and then return to the main interface.
 